Daikin Bulkhead Ducted System

Available in
Reverse Cycle (Heating & Cooling)
Capacities
2.5kW, 3.5kW, 5.0kW, 6.0kW, 7.1kW
Refrigerant
R32
The Bulkhead range is the ideal choice for air conditioning areas where a discreet installation is preferred. The indoor unit fits flush into the ceiling with only the suction air and discharge grilles visible inside your home and leaving maximum floor and wall space for furniture, decoration and fittings. The Bulkhead range is truly discreet with whisper quiet operations to ensure limited impact to internal room aesthetics and acoustics.
Categories: ,

Key Features

Compact Performance

Offering maximum performance in a compact, 450mm deep package, this model is idea for wardrobe installations.

Quiet Operation

Noise levels are truly discreet and whisper quiet at 19dBA (low fan speed, 35 Class Model).

Australian Made

Indoor units are specifically designed and manufactured to Australian standards to withstand the harsher summer climate.

Built-in condensate pump

DC condensate pump is equipped as standard with a 750mm lift.

3-D Auto Swing Grille (Option)

Vertical & horizontal motorised louvres installed provide 3-D airflow distribution, circulating air to all corners of the room.Vertical & horizontal motorised louvres installed provide 3-D airflow distribution, circulating air to all corners of the room.*BDG20A09A1 for 25 Class, BDG20A15A1 for 35-50 Class & BDG20A20A1 for 60-71 Class. Only compatible with BRC1E63 controller.

Auto Clean Air Filter Module (Option)

This module keeps the internal filter clean by collecting dust and storing it in a convenient vacuum port for easy removal.^BAE20A62 for 25 Class, BAE20A82 for 35-50 Class & BAE20A102 for 60-71 Class (all models extend depth by 188mm). Only compatible with BRC1E63 controller.

Technical Specs

INDOOR UNIT FDYBA25AV1 FDYBA35AV1 FDYBA50AV1 FDYBA60AV1 FDYBA71AV1
OUTDOOR UNIT RZAC25G2V1 RZAC35G2V1 RZAC50G2V1 RZAC60G2V1 RZAC71G2V1
Rated Capacity Cool (kW) 2.50 3.50 5.00 6.00 7.10
Heat (kW) 3.50 4.00 6.00 7.00 8.00
Capacity Range Cool (kW) 0.8-2.8 0.8-4.0 1.6-6.2 2.0-6.7 1.7-7.6
Heat (kW) 0.9-3.7 1.0-4.3 1.5-7.4 2.0-8.0 1.4-8.6
Power Input (Rated) Cool (kW) 0.60 1.02 1.37 1.70 2.12
Heat (kW) 0.97 1.11 1.73 1.80 2.22
E.E.R/C.O.P C/H 4.17/3.61 3.45/3.60 3.65/3.47 3.53/3.89 3.35/3.60
TCSPF (Residential) Hot/Average/Cold 4.82/4.11/4.04 4.37/3.88/3.92 5.09/4.20/4.19 5.21/4.38/4.45 4.61/4.26/4.41
HSPF (Residential) Hot/Average/Cold 4.29/3.64/3.05 4.53/4.06/3.69 4.76/4.12/3.58 5.28/4.58/3.98 6.09/4.13/3.28
Airflow Rate (Rated) l/s 150 195 240 325 325
Indoor Sound Level (H) @ 1.5m Discharge (dBA) 41.6 43.1 45.3 47.7 47.7
Suction (dBA) 40.8 38.9 41.2 46.2 46.2
Casing Breakout (dBA) 30.1 31.6 33.8 35.6 35.6
Piping Length m 20 20 30 30 30
Indoor Fan Speeds 5 Steps, Quiet and Automatic
Dimensions (HxWxD) Indoor (mm) 200x700x450 200x900x450 200x1100x450
Outdoor (mm) 550x675x284 595x845x300 695x930x350
Weight Indoor (kg) 18 21 24
Outdoor (kg) 28 45 54
Power Supply V/Hz 1 Phase 220-240V, 50Hz
Compressor Type Hermetically Sealed Swing Type
Refrigerant R32
Pipe Sizes Liquid (mm) 6.4 (Flared) 6.4 (Flared)
Gas (mm) 9.5 (Flared) 12.7 (Flared)
Drain (mm) ID 20 / OD 26
Supply Air Opening mm (HxW, Flange) 153x660 153x860 153x1060
Return Air Opening mm (HxW) 163x575 163x775 163x975
Outdoor Operating Range Cool (°CDB) -10 to 50
Heat (°CWB) -15 to 18
EPA Sound Power Level dBA 60 60 62 63 67
Outdoor Sound Level (H) @ 1m Pressure dBA (C/H) 45/48 47/48 47/50 48/51 53/55

Get A Quick Quote

  • This field is for validation purposes and should be left unchanged.